MP801 Air-Quality Gas Sensor


Target:air quality:C6H6、C7H8、CH2O、C2H5OH、smoke
Modle:MP801
Detection range:0.5-1000ppm(C2H5OH)
Detection principle:Semiconductor
Characteristics:High sensitivity to C6H6、C7H8、CH2O、C2H5OH、smoke
Size:φ9.4×7
Working conditions:Loop Voltage:≤24V Heater Voltage:5±0.1V Heater consumption:≤300mW

Description

MP801 gas sensor is for air quality. It adopts multilayer thick film manufacturing technology. The heater and metal oxide semiconductor material on the ceramic substrate of subminiature Al2O3 are fetched out by electrode down-lead, encapsulated in metal socket and cap. Conductivity of the sensor is affected by the concentration of target gas. The higher the concentration is, the higher conductivity of sensor gets. Users can adopt simple circuit to convert variation of conductivity into output signal corresponding to gas concentration.

Application

It is used in occasions such as household and office for harmful gas detection, automatic exhaust device, air cleaner&etc.

Features

High sensitivity to benzene,toluene,alcohol, smoke; quick response and resume; low power consumption, simple detection circuit, good stability and long life.

Specifications

ModelMP801
Sensor TypeSemiconductor flat surfaced sensor
Standard EncapsulationMetal Cap
Detection Gasbenzene,toluene,methanal,alcohol, smoke
Detection range0.5~1000ppm(alcohol)
Standard circuitLoop voltageVC≤24V DC
Heating voltage VH 5.0V±0.1VAC orDC
Load resistanceRLAdjustable
sensor features in standard test conditionHeating resistanceRH95Ω±10Ω(Room Temp.)
Heating consumptionPH≤300mW
Surface resistanceRS1KΩ~15KΩ(in 10ppm alcohol)
SensitivitySRs(in air)/Rs(in 10ppm alcohol)≥2
Concentration slopeα≤0.6(R50ppm/R10ppm alcohol)
Standard condition of testTemperature, humidity20℃±2℃;65%±5%RH
Standard test circuitVC/VH :5.0V±0.1V
Warm-up timeMore than 48 hours

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.